{"product_id":"nevada-iii-electric-unit-heater","title":"Nevada III Electric Unit Heater","description":"\u003cp dir=\"ltr\"\u003eThe Nevada III is a wall mounted electric fan heater for warehouses, workshops, halls and trade counters. Six outputs from 4.5kW to 20kW, with adjustable discharge segments to aim warm air where it is needed. Runs on a 400V supply and ships complete with the ECON control and matching bracket.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eAir volume\u003c\/th\u003e\n\u003cth\u003eOutlet air temp\u003c\/th\u003e\n\u003cth\u003eFan input\u003c\/th\u003e\n\u003cth\u003eFan current\u003c\/th\u003e\n\u003cth\u003eNoise at 5m\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1E 4.5kW\u003c\/td\u003e\n\u003ctd\u003e2,225 m³\/h\u003c\/td\u003e\n\u003ctd\u003e16°C\u003c\/td\u003e\n\u003ctd\u003e165W\u003c\/td\u003e\n\u003ctd\u003e0.9A\u003c\/td\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003ctd\u003e19kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1E 6kW\u003c\/td\u003e\n\u003ctd\u003e2,225 m³\/h\u003c\/td\u003e\n\u003ctd\u003e18°C\u003c\/td\u003e\n\u003ctd\u003e165W\u003c\/td\u003e\n\u003ctd\u003e0.9A\u003c\/td\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003ctd\u003e19kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1E 7.5kW\u003c\/td\u003e\n\u003ctd\u003e2,225 m³\/h\u003c\/td\u003e\n\u003ctd\u003e20°C\u003c\/td\u003e\n\u003ctd\u003e165W\u003c\/td\u003e\n\u003ctd\u003e0.9A\u003c\/td\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003ctd\u003e19kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2E 10kW\u003c\/td\u003e\n\u003ctd\u003e3,650 m³\/h\u003c\/td\u003e\n\u003ctd\u003e18°C\u003c\/td\u003e\n\u003ctd\u003e260W\u003c\/td\u003e\n\u003ctd\u003e1.4A\u003c\/td\u003e\n\u003ctd\u003e58 dB(A)\u003c\/td\u003e\n\u003ctd\u003e26kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2E 15kW\u003c\/td\u003e\n\u003ctd\u003e3,650 m³\/h\u003c\/td\u003e\n\u003ctd\u003e22°C\u003c\/td\u003e\n\u003ctd\u003e260W\u003c\/td\u003e\n\u003ctd\u003e1.4A\u003c\/td\u003e\n\u003ctd\u003e58 dB(A)\u003c\/td\u003e\n\u003ctd\u003e26kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2E 20kW\u003c\/td\u003e\n\u003ctd\u003e3,650 m³\/h\u003c\/td\u003e\n\u003ctd\u003e26°C\u003c\/td\u003e\n\u003ctd\u003e260W\u003c\/td\u003e\n\u003ctd\u003e1.4A\u003c\/td\u003e\n\u003ctd\u003e58 dB(A)\u003c\/td\u003e\n\u003ctd\u003e28kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOutlet air temperature is quoted with intake air at 10°C.\u003c\/p\u003e\n\u003ch3\u003eDimensions and coverage\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth\u003eNevada III 1E (4.5 to 7.5kW)\u003c\/th\u003e\n\u003cth\u003eNevada III 2E (10 to 20kW)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e570mm\u003c\/td\u003e\n\u003ctd\u003e720mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e470mm\u003c\/td\u003e\n\u003ctd\u003e600mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e600mm\u003c\/td\u003e\n\u003ctd\u003e630mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum tilt in bracket\u003c\/td\u003e\n\u003ctd\u003e16 degrees\u003c\/td\u003e\n\u003ctd\u003e12 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting height\u003c\/td\u003e\n\u003ctd\u003eup to 3.9m\u003c\/td\u003e\n\u003ctd\u003eup to 4.2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir throw\u003c\/td\u003e\n\u003ctd\u003eup to 7.2m\u003c\/td\u003e\n\u003ctd\u003eup to 7.7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMounting height and throw are quoted at a 10°C difference between outlet and room temperature. Both figures increase at smaller temperature differences.\u003c\/p\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003cth\u003eSupply cable\u003c\/th\u003e\n\u003cth\u003eCircuit protection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.5kW, 6kW, 7.5kW\u003c\/td\u003e\n\u003ctd\u003e5C x 2.5mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 10A type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10kW, 15kW\u003c\/td\u003e\n\u003ctd\u003e5C x 4mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 16A type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20kW\u003c\/td\u003e\n\u003ctd\u003e5C x 4mm² and 5C x 6mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 16A and 3 x 25A type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe electric heater runs on 400V 50Hz three phase. The fan itself runs on 230V. Each unit has two heater sections wired on separate circuits, which is why two cable and breaker ratings are given for the 20kW model. Installation and connection must be carried out by a qualified electrician.\u003c\/p\u003e\n\u003ch3\u003eControls\u003c\/h3\u003e\n\u003cp\u003eThe TP1 basic room thermostat is available separately where on and off temperature control is required.\u003c\/p\u003e","brand":"Stavoklima","offers":[{"title":"4.5kW","offer_id":54017112834395,"sku":"MP-STAV-NEVADAIII-4.5kw-3Phz","price":901.0,"currency_code":"GBP","in_stock":false},{"title":"6kW","offer_id":54017112867163,"sku":"MP-STAV-NEVADAIII-6.0kw-3Phz","price":989.0,"currency_code":"GBP","in_stock":false},{"title":"7.5kW","offer_id":54017112899931,"sku":"MP-STAV-NEVADAIII-7.5kw-3Phz","price":1112.0,"currency_code":"GBP","in_stock":false},{"title":"10kW","offer_id":54017112932699,"sku":"MP-STAV-NEVADAIII-10kw-3Phz","price":1143.0,"currency_code":"GBP","in_stock":false},{"title":"15kW","offer_id":54017112965467,"sku":"MP-STAV-NEVADAIII-15kw-3Phz","price":1450.0,"currency_code":"GBP","in_stock":false},{"title":"20kW","offer_id":54017112998235,"sku":"MP-STAV-NEVADAIII-20kw-3Phz","price":1938.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0882\/8089\/1739\/files\/obr.-23.jpg?v=1788959387","url":"https:\/\/shop.turnbull-scott.co.uk\/products\/nevada-iii-electric-unit-heater","provider":"Turnbull \u0026 Scott","version":"1.0","type":"link"}